Two ratings, two loads
SEER2 is seasonal cooling output per watt-hour of electricity; HSPF2 is the heating equivalent. The calculator divides each annual Btu load by its corresponding rating. With the load and every other input held constant, a higher rating gives a lower modeled kWh figure for that season.
For 24,000,000 Btu of annual cooling at SEER2 16, the model gives 24,000,000 ÷ 16 ÷ 1,000 = 1,500 kWh. Heating is calculated separately with HSPF2, then added.
Use the rating system shown on the equipment
Use SEER2 and HSPF2 from the documentation for the indoor and outdoor components quoted together. Older SEER and HSP numbers come from different test procedures. The calculator does not convert them; ask the installer for the matched system's SEER2 and HSPF2 figures.
Why the label will not predict a bill
Seasonal ratings come from standardized tests. Your electricity use will also depend on weather, load, controls, installation, ducts and any auxiliary heat. The DOE/FEMP examples show how ratings change sample annual kWh when operating hours stay fixed. They do not measure a particular home.
Our formula has no separate cold-weather or backup-heat adjustment. Read how it produces an annual cost, or try your own ratings in the calculator.